Planmeca ProMax 2D S2

The Extraoral Bitewing Story: Planmeca introduced the most efficient and diagnostic EXTRAORAL bitewings to 2D routine imaging. User interface provides guidance The full-color graphical user interface provides clear texts and symbols to guide you through your procedure. Settings are logically grouped and easy to understand, speeding up imaging and allowing you to focus on your patients. Easy patient positioning Open patient positioning… Read more


Promotions

All Equipment Promotions


Literature

Planmeca 2D Imaging Brochure

Planmeca Accurate Diagnostics, Safer Imaging

Planmeca Responsible Radiation

Planmeca Romexis® Software

Planmeca True Extraoral Bitewings

The Extraoral Bitewing Story:

Planmeca introduced the most efficient and diagnostic EXTRAORAL bitewings to 2D routine imaging.

User interface provides guidance

The full-color graphical user interface provides clear texts and symbols to guide you through your procedure. Settings are logically grouped and easy to understand, speeding up imaging and allowing you to focus on your patients.

Easy patient positioning

Open patient positioning and side entry minimize errors caused by incorrect patient positioning, allowing you to monitor the patient freely from both the front and side. Side entry allows easy access for all patients – standing or seated. Patient positioning is assisted by our triple laser beam system, which indicates the correct anatomical positioning points.

All the imaging programs you need

Our Planmeca ProMax® X-ray unit offers the widest variety of imaging programs available – easily meeting all your clinical needs. You can also select the correct exposure formats to minimize the radiation dose for all types of patients and diagnostic purposes.

Standard: Basic panoramic programs

Standard panoramic
Lateral TMJ (closed & open)
PA TMJ (closed & open)
PA sinus

Standard 

Child (Pediatric) mode for each standard and optional program to reduce the dose

Optional 

Horizontal and vertical segmenting for panoramic program

Optional 

Bitewing

Panoramic imaging

Standard panoramic program.

Extraoral bitewings

The Bitewing program uses improved interproximal angulation geometry. The result is a bitewing image pair with low patient dose and excellent diagnostic quality.

Sinus imaging

The Sinus programs provide a clear view of the maxillary sinuses.

Horizontal and vertical segmenting for panoramic program

With the Horizontal and vertical segmenting program, exposure can be strictly limited to the diagnostic region of interest. Patient dosage is reduced by up to 90% compared to full panoramic exposure.

TMJ imaging

The TMJ imaging programs produce lateral or posteroanterior views of open or closed temporomandibular joints. The imaging position can be adjusted to correspond to the anatomy of each individual patient.

Child mode for reduced dose

Child mode reduces the patient dose remarkably for all programs by reducing the imaging area and exposure values.

Easy upgrade from 2D to 3D

Planmeca ProMax® – future proof and a great investment

Planmeca ProMax® 2D is designed with upgradeability in mind. The unit’s modular structure allows easy conversion to different imaging modalities, while the software-driven SCARA is extremely flexible, allowing you to benefit from new imaging projections.

Whether you’re upgrading your 2D unit to 3D, or adding a cephalometric arm, Planmeca has the right solution for you. Individual options can be installed before delivery or added later, making Planmeca ProMax the most versatile all-in-one X-ray unit available.

Imaging programs

Standard: Basic panoramic programsStandard panoramic
Lateral TMJ (closed & open)
PA TMJ (closed & open)
PA sinus
Standard Child (Paediatric) mode for each standard and optional program to reduce the dose
Optional Horizontal and vertical segmenting for panoramic program
Optional Bitewing

Technical data

GeneratorConstant potential, resonance mode high frequency
80–150 kHz
X-ray tubeD-054SB-P
Focal spot size
0.5 x 0.5 mm (IEC 336)
Total filtrationmin. 2.5 mm Al equivalent
Anode voltage50–84 kV
Anode current0.5–16 mA DC
Exposure timePan2.7–16 s
Scanning ceph6.4–9.9 s
Planmeca ProCeph0.1–0.8 s
Tomo3 s / frame
SIDPan500 mm (19 in.)
Ceph163–170 cm (64–67 in.)
MagnificationPanconstant 1.2
Ceph1.08–1.13
CCD pixel size48 µm
Image pixel size48/96/144 µm selectable
CCD active surfacePan6 x 147 mm
Ceph6 x 295 mm
Resolution (digital)Panmax. 9 lp/mm
Cephmax. 5.7 lp/mm
Image field (digital)Pan14 x 30 cm (5.5 x 12 in.)
Ceph24/27 x 18/30 cm
(9/10.6 x 7/11.8 in.)
File size, un­compressed (digital)Pan4–33 MB
Ceph7–16 MB
Line voltage100–240 V, 50 or 60 Hz
RegulationAutomatic, ±10 %
Line current8–16 A
Colour White (RAL 9016)

Physical space requirements

Planmeca ProMax 2DPlanmeca ProMax 2D with cephalostat
Width96 cm (38 in.)194 cm (76 in.)
Depth125 cm (49 in.)125 cm (49 in.)
Height*153–243 cm (60–96 in.)153–243 cm (60–96 in.)
Weight113 kg (lbs 248)128 kg (lbs 282)

Minimum operational space requirements

Planmeca ProMax 2DPlanmeca ProMax 2D with cephalostat
Width150 cm (59 in.)215 cm (85 in.)
Depth163 cm (64 in.)163 cm (64 in.)
Height*243 cm (96 in.)243 cm (96 in.)

*The maximum height of the unit can be adjusted for offices with limited ceiling space.

Dimensions

ProMax 2D S3 Dimensions